UPAD00ITA Site Information Form (site log v2.0)
International GNSS Service
See Instructions at:
https://files.igs.org/pub/station/general/sitelog_instr_v2.0.txt
0. Form
Prepared by (full name) : Prof. Alessandro Caporali
Date Prepared : 2012-01-09
Report Type : UPDATE
If Update:
Previous Site Log : upad00ita_20060321.log
Modified/Added Sections : 11, 13
1. Site Identification of the GNSS Monument
Site Name : University of Padova, Main Building
Nine Character ID : UPAD00ITA
Monument Inscription :
IERS DOMES Number : 12750M002
CDP Number : (A4)
Monument Description : MAST
Height of the Monument : 1.862 m
Monument Foundation : ROOF
Foundation Depth : 10 m
Marker Description : NAIL
Date Installed : 1997-12-23
Geologic Characteristic : GRAVEL
Bedrock Type : SEDIMENTARY
Bedrock Condition : (FRESH/JOINTED/WEATHERED)
Fracture Spacing : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm)
Fault zones nearby : NO
Distance/activity : (multiple lines)
Additional Information : New antenna replaces the previous
: on the same spot.
: No horizontal shift.
: Possible change in the vertical (mm level)
: due to different phase centres.
: On December 28, 1994, a new location for the
: antenna was adopted. This change was dictated
: by probable high multipath environment which
: existed in the configuration described in the
: LOGFILE UPAD0694.log. The new site is nearly
: five meters away from the 0694 location and
: seems much better (replaces 12750M001)
2. Site Location Information
City or Town : Padova
State or Province : N/A
Country or Region : ITA
Tectonic Plate : EURASIAN
Approximate Position (ITRF)
X coordinate (m) : 4389531.280
Y coordinate (m) : 923253.650
Z coordinate (m) : 4519256.350
Latitude (N is +) : +452424.18
Longitude (E is +) : +0115240.55
Elevation (m,ellips.) : 84.0
Additional Information : (multiple lines)
3. GNSS Receiver Information
3.1 Receiver Type : TRIMBLE 4000SSE
Satellite System : GPS
Serial Number : 3247A01926
Firmware Version : 7.22
Elevation Cutoff Setting : 15 deg
Date Installed : 1997-01-12
Date Removed : 1997-12-22T23:59Z
Temperature Stabiliz. : none
Additional Information : (multiple lines)
3.2 Receiver Type : TRIMBLE 4000SSI
Satellite System : GPS
Serial Number : 19459
Firmware Version : 7.25 / 3.07
Elevation Cutoff Setting : 15 deg
Date Installed : 1997-12-23T00:00Z
Date Removed : 1999-06-22T12:59Z
Temperature Stabiliz. : none
Additional Information : (multiple lines)
3.3 Receiver Type : TRIMBLE 4000SSI
Satellite System : GPS
Serial Number : 19459
Firmware Version : 7.25 / 3.07
Elevation Cutoff Setting : 15 deg
Date Installed : 1999-06-22T13:00Z
Date Removed : 2001-11-21
Temperature Stabiliz. : none
Additional Information : new firmware is expected to be compiant
: with GPS week 1024 rollover and Y2K
3.4 Receiver Type : TRIMBLE 4000SSI
Satellite System : GPS
Serial Number : 19459
Firmware Version : 7.25 / 3.07
Elevation Cutoff Setting : 15 deg
Date Installed : 2001-11-21T00:01Z
Date Removed : 2001-11-21T12:00Z
Temperature Stabiliz. : none
Additional Information : consistency in time with item 4.5
3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions)
Satellite System : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS)
Serial Number : (A20, but note the first A5 is used in SINEX)
Firmware Version : (A11)
Elevation Cutoff Setting : (deg)
Date Installed : (CCYY-MM-DDThh:mmZ)
Date Removed : (CCYY-MM-DDThh:mmZ)
Temperature Stabiliz. : (none or tolerance in degrees C)
Additional Information : (multiple lines)
4. GNSS Antenna Information
4.1 Antenna Type : TRM14532.00 NONE
Serial Number : 3241A64735
Antenna Reference Point : BPA
Marker->ARP Up Ecc. (m) : 1.9620
Marker->ARP North Ecc(m) : 0.0000
Marker->ARP East Ecc(m) : 0.0000
Alignment from True N : 0 deg
Antenna Radome Type : NONE
Radome Serial Number :
Antenna Cable Type : (vendor & type number)
Antenna Cable Length : 30 m
Date Installed : 1994-12-01
Date Removed : 1997-12-22T23:59Z
Additional Information : (multiple lines)
4.2 Antenna Type : TRM29659.00 NONE
Serial Number : 88300
Antenna Reference Point : BPA
Marker->ARP Up Ecc. (m) : 1.9620
Marker->ARP North Ecc(m) : 0.0000
Marker->ARP East Ecc(m) : 0.0000
Alignment from True N : 0 deg
Antenna Radome Type : NONE
Radome Serial Number :
Antenna Cable Type : (vendor & type number)
Antenna Cable Length : 30 m
Date Installed : 1997-12-23T00:00Z
Date Removed : 1998-08-13T00:00Z
Additional Information : (multiple lines)
4.3 Antenna Type : TRM29659.00 NONE
Serial Number : 88300
Antenna Reference Point : BPA
Marker->ARP Up Ecc. (m) : 1.9621
Marker->ARP North Ecc(m) : 0.0000
Marker->ARP East Ecc(m) : 0.0000
Alignment from True N : 0 deg
Antenna Radome Type : NONE
Radome Serial Number :
Antenna Cable Type : (vendor & type number)
Antenna Cable Length : 30 m
Date Installed : 1998-08-13T00:01Z
Date Removed : 1999-05-28T07:59Z
Additional Information : the 0.1 mm correction in the antenna height is
: introduced for consistence with the header of
: the RINEX files. No physical change is implied
: in the antenna mount.
4.4 Antenna Type : TRM29659.00 NONE
Serial Number : 88300
Antenna Reference Point : BPA
Marker->ARP Up Ecc. (m) : 1.9621
Marker->ARP North Ecc(m) : 0.0000
Marker->ARP East Ecc(m) : 0.0000
Alignment from True N : 0 deg
Antenna Radome Type : NONE
Radome Serial Number :
Antenna Cable Type : (vendor & type number)
Antenna Cable Length : 30 m
Date Installed : 1999-05-28T08:00Z
Date Removed : 1999-09-28T23:59Z
Additional Information : THE ID OF THE ANTENNA TYPE CONFORMS
: TO RCVR_ANT.TAB FILE
: AS SPECIFIED IN IGSMAIL#2281.
: NO PHYSICAL CHANGE IS OTHERWISE IMPLIED
: IN THE LOCATION OF THE ANTENNA
4.5 Antenna Type : TRM29659.00 NONE
Serial Number : 88300
Antenna Reference Point : BPA
Marker->ARP Up Ecc. (m) : 1.9621
Marker->ARP North Ecc(m) : 0.0000
Marker->ARP East Ecc(m) : 0.0000
Alignment from True N : 0 deg
Antenna Radome Type : NONE
Radome Serial Number :
Antenna Cable Type : (vendor & type number)
Antenna Cable Length : 30 m
Date Installed : 1999-09-29T00:00Z
Date Removed : 2001-11-21T12:00Z
Additional Information : (multiple lines)
4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions)
Serial Number : (A*, but note the first A5 is used in SINEX)
Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.)
Marker->ARP Up Ecc. (m) : (F8.4)
Marker->ARP North Ecc(m) : (F8.4)
Marker->ARP East Ecc(m) : (F8.4)
Alignment from True N : (deg; + is clockwise/east)
Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions)
Radome Serial Number :
Antenna Cable Type : (vendor & type number)
Antenna Cable Length : (m)
Date Installed : (CCYY-MM-DDThh:mmZ)
Date Removed : (CCYY-MM-DDThh:mmZ)
Additional Information : (multiple lines)
5. Surveyed Local Ties
5.x Tied Marker Name :
Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
Tied Marker CDP Number : (A4)
Tied Marker DOMES Number : (A9)
Differential Components from GNSS Marker to the tied monument (ITRS)
dx (m) : (m)
dy (m) : (m)
dz (m) : (m)
Accuracy (mm) : (mm)
Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc)
Date Measured : (CCYY-MM-DDThh:mmZ)
Additional Information : (multiple lines)
6. Frequency Standard
6.1 Standard Type : INTERNAL
Input Frequency : (if external)
Effective Dates : 2001-11-21/CCYY-MM-DD
Notes : (multiple lines)
6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc)
Input Frequency : (if external)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
7. Collocation Information
7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc)
Status : (PERMANENT/MOBILE)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8. Meteorological Instrumentation
8.1.x Humidity Sensor Model :
Manufacturer :
Serial Number :
Data Sampling Interval : (sec)
Accuracy (% rel h) : (% rel h)
Aspiration : (UNASPIRATED/NATURAL/FAN/etc)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.2.x Pressure Sensor Model :
Manufacturer :
Serial Number :
Data Sampling Interval : (sec)
Accuracy : (hPa)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.3.x Temp. Sensor Model :
Manufacturer :
Serial Number :
Data Sampling Interval : (sec)
Accuracy : (deg C)
Aspiration : (UNASPIRATED/NATURAL/FAN/etc)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.4.x Water Vapor Radiometer :
Manufacturer :
Serial Number :
Distance to Antenna : (m)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.5.x Other Instrumentation : (multiple lines)
9. Local Ongoing Conditions Possibly Affecting Computed Position
9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc)
Observed Degradations : (SN RATIO/DATA GAPS/etc)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Additional Information : (multiple lines)
9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Additional Information : (multiple lines)
9.3.x Signal Obstructions : (TREES/BUILDINGS/etc)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Additional Information : (multiple lines)
10. Local Episodic Effects Possibly Affecting Data Quality
10.x Date : (CCYY-MM-DD/CCYY-MM-DD)
Event : (TREE CLEARING/CONSTRUCTION/etc)
11. On-Site, Point of Contact Agency Information
Agency : Universitą di Padova
: Centro di Ateneo di Studi e Attivita Spaziali
: "G.Colombo"
Preferred Abbreviation : CISAS
Mailing Address : Via Venezia 15
: 35131 Padova
: Italy
Primary Contact
Contact Name : Prof. Alessandro Caporali
Telephone (primary) : +39 049 827 9122
Telephone (secondary) :
Fax : +39 049 827 9134
E-mail : [email protected]
Secondary Contact
Contact Name :
Telephone (primary) :
Telephone (secondary) :
Fax :
E-mail :
Additional Information : (multiple lines)
12. Responsible Agency (if different from 11.)
Agency : (multiple lines)
Preferred Abbreviation : (A10)
Mailing Address : (multiple lines)
Primary Contact
Contact Name :
Telephone (primary) :
Telephone (secondary) :
Fax :
E-mail :
Secondary Contact
Contact Name :
Telephone (primary) :
Telephone (secondary) :
Fax :
E-mail :
Additional Information : (multiple lines)
13. More Information
Primary Data Center : BKG
Secondary Data Center : ASI
URL for More Information :
Hardcopy on File
Site Map : X
Site Diagram : X
Horizon Mask : NO OBSTRUCTION ABOVE 0 DEGREES
Monument Description : (Y or URL)
Site Pictures : (Y or URL)
Additional Information : (multiple lines)
Antenna Graphics with Dimensions
TRM29659.00
Trimble L1/L2 Dorne Margolin element with chokerings
Model 29659.00
+-------+
/ + \ <-- 0.1280 L2
| + | <-- 0.1100 L1
+--------------------------------------------------+ <-- 0.1020 TCR
| |
| |
| |
| |
+-+--------------------------------------------------+-+ <-- 0.0380
+-------------------+-------------+--------------------+ <-- 0.0350 BCR
| |
| |
+------x------+ <-- 0.0 BPA=ARP
<-- 0.3810 -->
ARP: Antenna Reference Point
L1 : L1 Phase Center L2 : L2 Phase Center