COST00ROU Site Information Form (site log v2.0)
     International GNSS Service
     See Instructions at:
       https://files.igs.org/pub/station/general/sitelog_instr_v2.0.txt


0.   Form

     Prepared by (full name)  : Geodesy and ROMPOS Service ([email protected])
     Date Prepared            : 2024-11-19
     Report Type              : UPDATE
     If Update:
      Previous Site Log       : cost00rou_20241107.log
      Modified/Added Sections : 11


1.   Site Identification of the GNSS Monument

     Site Name                : Constanta
     Nine Character ID        : COST00ROU
     Monument Inscription     : 
     IERS DOMES Number        : 11407M001
     CDP Number               : (A4)
     Monument Description     : STEEL MAST
       Height of the Monument : 1.50 m
       Monument Foundation    : ROOF
       Foundation Depth       : (m)
     Marker Description       : (CHISELLED CROSS/DIVOT/BRASS NAIL/etc)
     Date Installed           : 2004-08-28T12:00Z
     Geologic Characteristic  : CONGLOMERATE
       Bedrock Type           : SEDIMENTARY
       Bedrock Condition      : WEATHERED
       Fracture Spacing       : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm)
       Fault zones nearby     : NO
         Distance/activity    : (multiple lines)
     Additional Information   : The GPS station Constanta is located on
                              : the top of the Port Museum 'Queen Nest'
                              : close to the digital tide gauge on
                              : Black Sea.


2.   Site Location Information

     City or Town             : Constanta
     State or Province        : Constanta
     Country or Region        : ROU
     Tectonic Plate           : EURASIAN
     Approximate Position (ITRF)
       X coordinate (m)       : 4021614.040
       Y coordinate (m)       : 2197896.088
       Z coordinate (m)       : 4421014.485
       Latitude (N is +)      : +440941.39
       Longitude (E is +)     : +0283927.09
       Elevation (m,ellips.)  : 46.2
     Additional Information   : (multiple lines)


3.   GNSS Receiver Information

3.1  Receiver Type            : ASHTECH Z-X
     Satellite System         : GPS
     Serial Number            : ZE120024621
     Firmware Version         : ZE000A13
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2004-08-28T12:00Z
     Date Removed             : 2013-12-18T10:30Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : On 22 Sept. 2010, deleted 6 blank digits from
                              : the firmware version due to the new software
                              : installed on local computer, not supporting
                              : blanks between letters. Old: 'ZE00
                              : 0A13'; New: 'ZE000A13'. No receiver
                              : firmware change !

3.2  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 496988
     Firmware Version         : 8.51/6.110
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2013-12-18T12:00Z
     Date Removed             : 2019-04-24T07:30Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.3  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 496988
     Firmware Version         : 9.20/6.404
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2019-04-24T07:40Z
     Date Removed             : 2019-06-06T11:55Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.4  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 496988
     Firmware Version         : 9.20/6.405
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2019-06-06T12:00Z
     Date Removed             : 2020-03-20T07:16Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.5  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 496988
     Firmware Version         : 9.20/6.405
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2020-03-20T07:17Z
     Date Removed             : 2020-03-22T10:51Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.6  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 496988
     Firmware Version         : 9.20/6.407
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2020-03-22T11:07Z
     Date Removed             : 2021-01-25T09:55Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.7  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO+GAL
     Serial Number            : 496988
     Firmware Version         : 9.20/6.407
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2021-01-25T10:00Z
     Date Removed             : 2024-06-11T11:50Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.8  Receiver Type            : LEICA GR50
     Satellite System         : GPS+GLO+GAL+BDS
     Serial Number            : 2092115
     Firmware Version         : 4.80/7.900
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2024-06-11T12:09Z
     Date Removed             : 2024-10-15T08:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.9  Receiver Type            : LEICA GR50
     Satellite System         : GPS+GLO+GAL+BDS
     Serial Number            : 1870345
     Firmware Version         : 4.35/7.504
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2024-10-15T08:04Z
     Date Removed             : 2024-11-07T07:57Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.10 Receiver Type            : LEICA GR50
     Satellite System         : GPS+GLO+GAL+BDS
     Serial Number            : 2092115
     Firmware Version         : 4.81/7.900
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2024-11-07T08:03Z
     Date Removed             : CCYY-MM-DDThh:mmZ
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.x  Receiver Type            : (A20, from rcvr_ant.tab; see instructions)
     Satellite System         : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS)
     Serial Number            : (A20, but note the first A5 is used in SINEX)
     Firmware Version         : (A11)
     Elevation Cutoff Setting : (deg)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Temperature Stabiliz.    : (none or tolerance in degrees C)
     Additional Information   : (multiple lines)


4.   GNSS Antenna Information

4.1  Antenna Type             : ASH701945B_M    NONE
     Serial Number            : 5200428010
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.0380
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : NONE
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : 30 m
     Date Installed           : 2004-08-28T12:00Z
     Date Removed             : 2013-12-18T10:30Z
     Additional Information   : On 22 Sept. 2010, deleted first 2 digits from
                              : the antenna serial number due to the new
                              : software installed on local computer, not
                              : supporting more than 12 characters. Old:
                              : 'CR5200428010'; New:
                              : '5200428010'. No antenna change !

4.2  Antenna Type             : LEIAT504GG      NONE
     Serial Number            : 200648
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.0380
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : NONE
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : (m)
     Date Installed           : 2013-12-18T11:30Z
     Date Removed             : 2024-06-11T11:50Z
     Additional Information   : (multiple lines)

4.3  Antenna Type             : LEIAR20         LEIM
     Serial Number            : 25292013
     Antenna Reference Point  : BAM
     Marker->ARP Up Ecc. (m)  :   0.0380
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : LEIM
     Radome Serial Number     : 
     Antenna Cable Type       : coaxial
     Antenna Cable Length     : 30 m
     Date Installed           : 2024-06-11T12:09Z
     Date Removed             : CCYY-MM-DDThh:mmZ
     Additional Information   : (multiple lines)

4.x  Antenna Type             : (A20, from rcvr_ant.tab; see instructions)
     Serial Number            : (A*, but note the first A5 is used in SINEX)
     Antenna Reference Point  : (BPA/BCR/XXX from "antenna.gra"; see instr.)
     Marker->ARP Up Ecc. (m)  : (F8.4)
     Marker->ARP North Ecc(m) : (F8.4)
     Marker->ARP East Ecc(m)  : (F8.4)
     Alignment from True N    : (deg; + is clockwise/east)
     Antenna Radome Type      : (A4 from rcvr_ant.tab; see instructions)
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : (m)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


5.   Surveyed Local Ties

5.x  Tied Marker Name         : 
     Tied Marker Usage        : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : (m)
       dy (m)                 : (m)
       dz (m)                 : (m)
     Accuracy (mm)            : (mm)
     Survey method            : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc)
     Date Measured            : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


6.   Frequency Standard

6.1  Standard Type            : INTERNAL
       Input Frequency        : (if external)
       Effective Dates        : 2004-08-28/CCYY-MM-DD
       Notes                  : (multiple lines)

6.x  Standard Type            : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc)
       Input Frequency        : (if external)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


7.   Collocation Information

7.x  Instrumentation Type     : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc)
       Status                 : (PERMANENT/MOBILE)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


8.   Meteorological Instrumentation

8.1.x  Humidity Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy (% rel h)     : (% rel h)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.2.x  Pressure Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (hPa)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.3.x  Temp. Sensor Model     : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (deg C)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.4.x  Water Vapor Radiometer : 
       Manufacturer           : 
       Serial Number          : 
       Distance to Antenna    : (m)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.5.x  Other Instrumentation  : (multiple lines)


9.   Local Ongoing Conditions Possibly Affecting Computed Position

9.1.x  Radio Interferences    : (TV/CELL PHONE ANTENNA/RADAR/etc)
       Observed Degradations  : (SN RATIO/DATA GAPS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.2.x  Multipath Sources      : (METAL ROOF/DOME/VLBI ANTENNA/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.3.x  Signal Obstructions    : (TREES/BUILDINGS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)


10.  Local Episodic Effects Possibly Affecting Data Quality

10.x  Date                    : (CCYY-MM-DD/CCYY-MM-DD)
      Event                   : (TREE CLEARING/CONSTRUCTION/etc)


11.  On-Site, Point of Contact Agency Information

     Agency                   : National Center for Cartography
                              : Geodesy and ROMPOS Service
     Preferred Abbreviation   : NCC
     Mailing Address          : Expozitiei Bvd. 1A
                              : 012101 Bucharest
                              : Romania
     Primary Contact
       Contact Name           : Geodesy and ROMPOS Service
       Telephone (primary)    : +40 21 224 39 67
       Telephone (secondary)  : +40 758 071 894
       Fax                    : 
       E-mail                 : [email protected]
     Secondary Contact
       Contact Name           : Mr. Miluta Flueras
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : [email protected]
     Additional Information   : (multiple lines)




12.  Responsible Agency (if different from 11.)

     Agency                   : (multiple lines)
     Preferred Abbreviation   : (A10)
     Mailing Address          : (multiple lines)
     Primary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Secondary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Additional Information   : (multiple lines)


13.  More Information

     Primary Data Center      : BKG
     Secondary Data Center    : BKG
     URL for More Information : https://rompos.ro/index.php/en/technical-info/ro
                              : mpos-cors-map
     Hardcopy on File
       Site Map               : (Y or URL)
       Site Diagram           : (Y or URL)
       Horizon Mask           : (Y or URL)
       Monument Description   : https://rompos.ro/index.php/en/technical-info/ro
                              : mpos-cors-map/35-spgnss/18-cost
       Site Pictures          : https://rompos.ro/index.php/en/technical-info/ro
                              : mpos-cors-map/35-spgnss/18-cost
     Additional Information   : (multiple lines)
     Antenna Graphics with Dimensions

LEIAR20

                        +-----+                           <--  0.1613
                      /         \
                     |           |
    +----------------+-----------+----------------+       <--  0.1113  TCR
    |                                             |
    |                                             |
    |                                             |
    |                                             |
  +-+---------------------------------------------+-+
  +------------------+-----------+------------------+     <--  0.0323  BCR
                     |           |
                     |           |
                     +----+ +----+                        <--  0.0013  BPA
                          +x+                             <--  0.0000  BAM=ARP
                                                                       NOM=NRP
  <--                    0.3200                   -->